Problem:
The WebLogic Server does not start. Following errors seen in stdout/stderr/server logs:
<21-Jun-2009 08:18:13 o’clock BST> <Warning> <Security> <BEA-090066> <Problem handling boot identity. The following exception was generated: weblogic.security.internal.SerializedSystemIniException: [Security:090207]Version mismatch. have 117, expected 1>
.
.
Background & Analysis:
Read this tutorial to understand how a WebLogic server uses SerializedSystemIni.dat and how this file may become corrupted.
Solution:
Restore a backup of SerializedSystemIni.dat and start the WebLogic servers.
If you do not have a backup, then you will need to reconfigure the domain.
Root Cause:
The WebLogic domain’s SerializedSystemIni.dat file is corrupted.
NOTE:
(1) The solution above describes a successful problem-solving experience and may not be applicable to other problems with similar symptoms.
(2) Your rating of this post will be much appreciated. Also, feel free to leave comments.
Thank you very much! I shall try it out tomorrow!,lucy